The advanced positioning of the Zenith7000APS allows the bed to go into numerous positions for:
• Positively influencing clinically driven outcomes through multiple positioning options
• Accommodating post-surgical rehab positioning to facilitate resident comfort
• Reduces caregiver strain and potential injuries to caregiver and residents caused by manually repositioning residents
Designed for comfort and efficient operation
Height travel range: 8.75'' to 27''
Straight vertical rise protects walls and maintains footprint.
Timesaver Technology™ - fast motors save time.
Strong, no-sag grid deck sleep surface with sturdy cross braces.
Safe work load: 500 pounds*
Sealed ball bearings in over 20 locations ensure maintenance-free, continuous, silent operation
Bed provides 360° mobility at ANY height, ideal for cleaning under the bed.
Head and foot boards are securely mounted with tall, tubular mounting reduces breakage, creating a built-in push bar.
Bed locks and rolls at any height, reducing caregiver back strain.
Tool-less assembly reduces set-up time.
Multiple positioning such as lounge chair and recliner style functionality provides comfort and relaxation to the resident and also allows for positioning of resident closer to the caregiver for proper care.
The Cardiac Chair is primarily designed for residents with heart and respiratory problems to whom a semi-erect position brings great relief. The chair can be made to serve as a fully reclined bed when needed, but can also be adjusted to form a chair. This “cardiac position” helps to elevate the patient from the waist up, which provides relief to the lungs, increases circulation, and assists the patient in coming from a fully prone position to a sitting position without causing harm or undue strain.
***
Common features of the Zenith7100APS and Zenith7200APS
Maximum underbed clearance for use with overbed tables and lifts.
Synchronized high-low motors keep the bed level for proper therapeutic positioning. When the head position is lower than the heart, lung volume may be compromised, causing airway problems, making it more difficult to breathe. Unlevel sleep surfaces may cause a risk of brain swelling and reduced systolic and diastolic pressures.
Pendant Hand Control and Holster Easy operation contoured pendant is shock-resistant, splash-proof and durable. On the Zenith7200APS, pendant connects to either side of the bed to adapt to varying room layouts. Holster conveniently secures to bedrails and assist devices for easy access.
Grounded bed with right-angle hospital-grade plug is a standard feature.
***
Features of the Zenith7200APS only
Intuitive two-pedal locking system is centrally positioned and easily visible from a distance to ensure that the bed is locked. Pedal locks are readily accessible at ALL bed heights and widths, even in the lowest position. Bed rolls at any height reducing caregiver back strain.
Directional mechanism on front casters is accessible at all heights for ease in rolling the bed.
Trendelenburg and Reverse Trendelenburg positioning, ideal for rehab and subacute, provides therapeutic benefits that can aid in circulation and ease body discomfort. Trendelenburg also promotes gravity assist resident self positioning.
Bed automatically pauses when it returns to level from Trendelenburg, Reverse Trendelenburg or chair position.
Auto CPR functionality allows for ideal CPR positioning in emergency situations.
Intuitive two-pedal locking system is centrally positioned and easily visible from a distance to ensure that the bed is locked. Pedal locks are readily accessible at ALL bed heights and widths, even in the lowest position. Bed rolls at any height reducing caregiver back strain.
Safety inspired embedded staff control in footboard
• Angled for better visibility.
• Two-stage lockouts – lockout of pendant use and lockout of embedded staff control.
• Quick lockout buttons lock multiple functions simultaneously.
• SafeMode™ automatically locks out high/low feature (unless disabled), Patents Pending.
***
SilverSolutions within the powder-coating provides antimicrobial surface protection
SilverSolutions inhibits the growth of organisms that can detract from the appearance and coating functionality:
• Inhibits the growth of bacterial odors
• Resists stains caused by mildew
• Resists stains caused by mold
SilverSolutions preserves the cured coating during the service life of the bed.
GF Health Products, Inc. makes no independent representations or empirical statements about SilverSolutions. This information is reprinted from: TCI Powder Coatings, EPA Guidance for EPA Registration 40 CFR 152.25
U.S. Patents
- Multiple Patents Pending
Proudly Made in America.
Height Travel Range…….………8.75'' to 27''
Safe Work Load*….................... 500 lbs.
Mattress Deck Length…….……. 76"/80"
Mattress Deck Width…………… 35"
Overall Bed Length (76"/80") ..…81.75"
Overall Bed Width.……………… 39" with assist bar
Overall Bed Width.…………….. 40.75" with half length assist
devices
Maximum back angle………….. 70° (Chair position 84°)
Maximum knee angle………….. 30°
* including resident, support surface, head/foot boards, and accessories.
SKUs
Please note that the pictures and descriptions on this page are representative of the product class. The stock codes below may be the product itself, or they may be associated stock codes related to the product being displayed. Please read the stock code description below to ensure you are ordering the correct item. Please call customer service if you have any questions regarding the correct stock code to choose.